Technical Support Newsletter - July 2008
If there are topics that you would like to see addressed please feel free to
provide us your suggestions; we would like this newsletter to provide useful and relevant information
for our users. Note: Some content links are authenticated and only available to
Customers and Partners of Nortel.
Continuing Series on Delivering World-class Support to our Customers
Customer Manual Recovery Program
Nortel is constantly striving to improve the delivery of technical support services.
This newsletter article focuses on a program to provide Customers and Partners with
training and tools that will more effectively help you resolve emergencies prior to ...
More
GENERAL NEWS
Training - The Key to Success
Training is the key to ensuring engineers provide Partners and Customers with fast and accurate
resolutions to their technical problems. Recently Nortel's Global Product Support teams have
put a focus on training...
More
Technical Support Requests for Nortel Commercial Tools
Nortel Commercial Tools are the various online tools which enable Nortel customers and partners to
quote, configure and order Nortel products. If you experience any technical problems with these tools
please send your support request to
ask@nortel.com. Your email
request ensures clear communication on both the issue and your contact information and will go
directly to the agent who can resolve your issue. When submitting your support email,
please include your contact information, tool name and the description of the issue.
Remember: Use
ask@nortel.com to ensure your
Nortel Commercial Tools technical support requests are processed as effectively as possible.
Lifecycle Bulletins Transitioning to Technical Support Website
In an ongoing effort to provide efficiency and a one-stop shop for our users, Nortel began
transitioning all End-of-Life and Manufacture Discontinued Product/Software bulletins to the
Technical Support web site as of June 1st. During this transition it is recommended that users
utilize the general search capabilities located at the top right of every Nortel web page when
searching for an EOL/MD bulletin. Once the transition is complete to the
Lifecycle Management
section of the Technical Support web site a News and Announcement article will be posted to our
web site.
DOCUMENTATION & TRAINING NEWS
New Nortel Converged Office - Nortel CS 1000/Microsoft OCS 2007 Training & Certification
Opportunities
Unified Communications simplify connectivity challenges by streamlining networks and integrating
services & applications, including voicemail, email, IM and conference calling. In support of
Unified Communications, a new
"Nortel Converged
Office - Nortel Communication Server (CS)1000/Microsoft OCS 2007 training & certification
curriculum" is available to ensure you have the knowledge you need to get the most out of your
solution. Why make it hard when you can make it simple?
Buy the VoIP Technologies Self-study Guide!
Looking for a reference on Voice over Internet Protocol (VoIP)? VoIP Technologies, your complete
guide to Voice over Internet Protocol (VoIP), provides a comprehensive foundation of VoIP
technology, as well as the knowledge necessary to successfully support any VoIP product. The guide
will also prepare the reader for the related certification exam.
http://www.nortel.com/corporate/news/publications/nortel_press/voip_tech.html
Buy The Business Communications Manager 50 Self-study Guide!
This guide has been designed for individuals involved in the sale or installation and configuration
of Business Communications Manager 50 systems. The guide will also prepare the reader for the
related certification exam.
http://www.nortel.com/corporate/news/publications/nortel_press/bcm50.html
CORE ENGINEERING - TIPS and TRICKS
Technology Briefs - Tips and Tricks
- Provisioning an Resilient Packet Ring (RPR) on an OM3500 shelf using dissimilar line
optics
When configuring an OPTera Packet Edge (OPE) in an OM3500 shelf the east and west facing optical
interfaces (OC-n) supporting the RPR do not have to be of the same type. For example, the east
facing interface could be an OC-48 and the west facing interface could be an OC-12, but the
cross-connect bandwidth configured for the RPR must be the same in each direction (e.g. STS-3c
to the east and STS-3c to the west).
- Configuring the OME6500 to accept external alarms using the SONET/SDH-J access panel
The OME6500 allows input telemetry pins on the SONET/SDH-J access panel to be used in
conjunction with Normally Open (NO) relays to raise alarms from external environmental sensors.
Determining which telemetry pins to use isn't always straight forward. Here are some things to
keep in mind when identifying the appropriate pins to use... More
- Prioritizing WLAN Client Traffic Using Wireless Multimedia Extension (WMM)
WMM, or Wireless Multimedia Extension, is a subset of the 802.11e standard that provides
Quality of Service (QoS) in Wireless LANs. Because wireless networks are a shared medium, similar
to an Ethernet hub in a wired environment... More
- CS1000 R5.5 MobileX
An integral component of Nortel's Fixed Mobile Convergence strategy, CS1000 R5.5 introduces
Mobile Extensions, or MobileX. MobileX extends enterprise voice services to the mobile
user... More
- CS1K FAXS (PKG-195)
Allows the passing of in-band Dual Tone Multi-Frequency (DTMF) digits to an external
device after answer, these digits can represent the originally dialed number (DNIS) of the
call... More
- Nortel Application Switch (NAS) - Downgrading "E" models to pre 22.0.8 code is dangerous
Recently a customer had asked if it was possible to use 22.0.2 code on their newly
acquired 3408E Nortel Application Switches. Due to standardization requirements within their
organization... More
- Nortel Application Switch (NAS) VPN Flood
VPN flood feature is used to support VPN traffic from main office to branch office with redirect
filter, RTS enabled and cache disabled. With this feature, traffic originating from the main office
will be forwarded to the correct branch office VPN router. NAS checks the session table and if the
session is not found and filter's action is redirect, NAS will send the packet to all real servers
in the group. With vpnflood enabled even though the destination was not identified by the NAS,
traffic will be forwarded to the correct VPN gateway.
/cfg/slb/filt X/adv/cache d
/c/slb/filt 1/adv/redir
vpnflood ena
- VPN Gateway Web Authentication
VPN gateway now supports external web authentication which can be used for portal, IPsec,
and Net Direct login. The following authentication schemes are supported: basic, digest and Nortel
Lan Manager (NTLM) Basic authentication is the original and most compatible authentication scheme
for HTTP and the least secure as it sends the username and password unencrypted. Digest
authentication is significantly more secure than basic authentication as it never transfers the
actual password across the network. The NTLM authentication method authenticates towards a Windows
server, Samba or Novell server.
- ERS5500 Virtual Link Aggregation Control Protocol (VLACP)
The ERS5000 supports Virtual Link Aggregation Control Protocol, VLACP to provide improved link
resiliency between switches. The ERS5500 uses a unique global VLACP Multicast MAC
address... More
- ERS4500 Spanning Tree Protocol (SPT) Bridge Protocol Data Unit (BPDU) Filtering
The ERS4500 support STP BPDU-Filtering; however this feature is disabled by default on all
switched ports.
The default configurable STP BPDU-Filtering timeout is displayed in 1/100 of a second with
a default value of 12000 which represents 2 minutes. The port will re-enable itself after 2 minutes
provided this event has cleared; however a value of zero (0) will keep the port down indefinitely.
BPDU-Filtering should be enabled on all user ports with a timeout set to zero (0) and should
remained disabled on MLT ports and core uplink ports.
- ERS8600 link-flap-detect
The ERS8600 supports link-flap-detect; however this feature is disabled by default in version 4.1.5.4.
The ERS8600 may have this feature dynamically enabled...
More
- ERS4500 with Bi-directional Transceiver (BX) Small Form-factor Pluggable (SFPs)
The ERS4500 running software version 5.1.0 "unofficially" supports BX style SFPs operating at
1490nm and 1320nm. ERS4500.s interoperate with a new BX style SFP which uses only one strand of
fiber to transmit and... More
- ERS8300 Advanced Filtering
The ERS8300 supports advanced filtering introduced in version 4.1.0 software release in conjunction
with 8394SF/CPU and newer I/O modules. The ERS8300 now has a boot flag that can...
More
- NAS Custom User Datagram Protocol (UDP) Domain Name Server (DNS) health checks
UDP based scripted health checks can be written to check content of the DNS server using binary
content. Following script sends query for host name 4.3.2.1.alt and expects response
address 1.1.1.1.
/c/slb/advhc/script 1
open "53,udp"
bsend "53 53 01 00 00 01 00 00"
nsend "00 00 00 00 01 34 01 33"
nsend "01 32 01 31 03 61 6c 74"
nsend "00 00 01 00 01"
bexpect "01 01 01 01"
offset "32"
depth "32"
wait "1024"
Queries
4.3.2.1.alt: type A, class IN
Name: 4.3.2.1.alt
Type: A (Host address)
Class: IN (0x0001)
0000 00 00 5e 00 01 c6 00 14 22 bb 12 f3 08 00 45 00 ..^.....".....E.
0010 00 39 9d 98 00 00 80 11 77 6a 2f 11 c6 7c 2f 10 .9......wj/..|/.
0020 01 14 0a 9f 00 35 00 25 57 79 00 05 01 00 00 01 .....5.%Wy......
0030 00 00 00 00 00 00 01 34 01 33 01 32 01 31 03 61 .......4.3.2.1.a
0040 6c 74 00 00 01 00 01 lt.....
- ERS 8600 Open Shortest Path First (OSPF) External Type 1 and Type 2 Routes
When redistributing external routes into OSPF, keep in mind that the ERS 8600, by default,
redistributes the routes as external type 2 routes. This may have some implications on the
routing behavior within the OSPF domain since type 2 routes do not take into account the path
cost within the OSPF domain. To route based on both the external path cost and the internal path
cost, you should redistribute external routes as type 1 routes.
- Communication Control Toolkit (CCT) integration with Genesys T-Server
Setting up CCT6 to interface with a Genesys T-Server that will communicate with the M-1 via the
Meridian Link Services Module (MLSM) link and provide call information to CCT that will be passed
on to IVR(MPS500) correctly and allow screen pops...
More
Frequently Asked Questions
Below are answers to questions that have been asked by our users via our surveys, contact us forms,
and through our technical support cases.
- I want to get access to Nortel documentation. How do I do this?
For Enterprise products, our documentation is available online without any requirement to
register for a UserID and password. Simply go to www.nortel.com/support and select your product
category or browse the products alphabetically. For other Nortel products, most technical
documentation requires Nortel customers and partners to be registered.
Go to www.nortel.com/register and complete
the form in its entirety. Ensure that you use your company email address since you will
receive a confirmation email containing important information
about your login. Once you have received the email, your account is set up.
- I thought I had an account to access Nortel documentation, but it is not working
or I can't remember my password. Who can I call?
Our customer service team at 1-800-4Nortel (option 5, 1) is there to help you with your questions
about your access. Give them your contact information as well as information about your company
(having a Site ID is very helpful) and they can help address your issues.
- There are issues with the content of a document. Is there way to report these issues on the
web?
Content issues may be reported through a number of channels including
www.nortel.com/documentfeedback. Please be as detailed as possible when providing information.
- I know the document number I am looking for. How can I find that document easily?
Use the Search Site box and enter the document number. This will give you search results with
documents that match that document number with higher relevance than in the document text.
- I want to provide feedback on the Nortel Website or your products, how can I do that quickly
and efficiently?
Completing a Contact Us Form is the easiest way to provide feedback on any number of
issues. Subject Matter Experts receive comments within 24 hours of submission and are
responsible to ensure that the correct department receives the feedback or resolves your
issue if one exists.
- I am in a product or solution category; can I search for a specific document here?
To search for a specific document number from one of the Nortel product or solution pages,
type all or part of the document number in the "Contains Text" box and then select the
"Number" radio button. A list of applicable documents will be presented on the same
screen below.