Registered Product configuration and testing notes for SmartNode Series by Patton Electronics with Communication Server 2000


The test effort verified a basic level of interoperability between the Patton Electronics - SmartNode 45xx Release R3.T, and Nortel’s Communication Server 2000 (CS 2000) Release SN09U. This successful testing establishes the Patton Electronics - SmartNode Series as a Nortel registered product for the releases tested. Testing included basic communication and basic call functionality between the devices. It is the service provider’s responsibility to perform appropriate system and network integration of the Patton Electronics SmartNode Series with the CS 2000 based on their network deployment requirements.

Test Exclusions:

- Redundancy, carrier grade, and traffic or robustness scenarios were not tested as these fall outside of basic interop testing.
- Voice quality was only checked through audible means between parties.


Limitations, Restrictions and Other Observations:

- SmartNode Series does not support conferencing, neither client-based nor network-based. 3WC/Conferencing test cases were not executed during this test event.

- SmartNode Series does not support the Decline feature. The Decline feature test case was not executed during this test event.

- SmartNode Series does support Consultative Call Transfer, but the SmartNode call flow differs from the reference call flows found in RFC draft-ietf-sip-cc-transfer-05. Issues with other Call Transfer scenarios may be found with further testing.


Nortel testing included:
Basic Communication using SIP

Basic Calls between SmartNode 45xx User Agents and calls to the PSTN

CS 2000 Feature Testing
- Calling Name and Number Delivery
- Calling Name and Number Delivery Blocking
- Basic Call Hold and Retrieve
- Basic Call Transfer
- Basic 3WC/Conferencing
- Basic Call Waiting



Compatible Product Disclaimer
directly for market availability of the Compatible Product in your area.

The Developer Product listed is verified in a laboratory environment as compatible with the indicated Nortel Product for a term of one (1) year from the date the Compatibility Test Audit was successfully completed as indicated above, until the Developer issues a new version of such Developer Product that incorporates new features or functionality or until Nortel issues a new version of such Nortel Product that incorporates new features or functionality, whichever occurs first. NORTEL MAKES NO REPRESENTATIONS, WARRANTIES OR CONDITIONS WITH RESPECT TO THE DEVELOPER PRODUCT OR THE NORTEL PRODUCT. WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, NORTEL HEREBY EXPRESSLY DISCLAIMS ANY AND ALL REPRESENTATIONS, WARRANTIES OR CONDITIONS OF ANY NATURE WHATSOEVER AS TO THE DEVELOPER PRODUCT AND THE NORTEL PRODUCT INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY, NON INFRINGEMENT OR FITNESS FOR A PARTICULAR PURPOSE AND NORTEL FURTHER SHALL HAVE NO LIABILITY TO DEVELOPER OR ANY OTHER PARTY ARISING FROM OR RELATED IN ANY MANNER TO THIS CERTIFICATE OF COMPATIBILITY. Nortel, the Nortel logo, and the Globemark are trademarks of Nortel Networks.