Compatible Product configuration and testing notes for USB Analog Terminal Adapter (ATA) with Business Communications Manager 200/400
The following Peripherals were not tested as part of the expansion of this product into EMEA. This exercise was completed as a subset of what was completed in North America
Peripherals Not Tested within EMEA:- Fax
- Modem
- External Lamp
- TTY
- Doorphone
North American Testing:
Compatibility with BCM is dependent on interface with users Nortel IP Softphone 2050 R2.0 Maintenance Release 254.
The following features were tested as part of the North American exercise.
- Basic Call Features : Caller ID, DTMF (Voicemail interaction)
- Split Control : Call Hold, Message Retrieval, Transfer, Conference
- Peripheral Testing : FAX, Modem, External Lamp, TTY, Doorphone
The tests were performed on the following Nortel platforms:
- Nortel Business Communications Manager (BCM) 200/400, Release 3.7
- Nortel Business Communications Manager (BCM) 200/400, Release 4.0 Compatible Product designation granted by technical review.
FAX support - T.38 fax is not supported in cases where IP trunks (SIP or H.323) are used
- Due to the nature of test results, it is recommended that if FAX be used with the USB-ATA, that transmission speeds of 9600 bps or less be used, with ECM turned off, to improve the likelihood of a successful 1st transmission. Transmissions at 300 bps may be most reliable.
TTY support - Despite some instances of garbled text for both calling and called parties, it is possible to conduct an intelligible TTY conversation
MODEM support - Modem connectivity at 300 bps demonstrated the best reliability, in terms of staying connected, as well as noise on the connection.
Calling/Called Party Name Display: - Name display is not supported. Only numbers will be displayed
DTMF - Incoming DTMF was not successful when the USB-ATA is connected an a trunk on a PBX.